When you do a reverse proxy in which
Nginx/varnish/ApacheBooster will be the one who listen the traffic and
forward anything needs to be process through PHP to Apache. With this,
Apache will always receive an IP from frontend server (or I should say
localhost / 127.0.0.1 / local IP/ server main IP), not the real IP that
user uses. In order to let Apache knows what is real user IP, we need to
install mod_rpaf, but the apache 2.4 is not suppoting current mod_rpaf
version, so you need to apply the following patch to work with
apache2.4.
save the above codes in text file and apply the patch using the following command.
--- mod_rpaf-2.0.c.org 2012-05-17 12:05:34.082130109 +0900 +++ mod_rpaf-2.0.c 2012-05-17 12:16:41.648138252 +0900 @@ -147,8 +147,8 @@ static apr_status_t rpaf_cleanup(void *data) { rpaf_cleanup_rec *rcr = (rpaf_cleanup_rec *)data; - rcr->r->connection->remote_ip = apr_pstrdup(rcr->r->connection->pool, rcr->old_ip); - rcr->r->connection->remote_addr->sa.sin.sin_addr.s_addr = apr_inet_addr(rcr->r->connection->remote_ip); + rcr->r->connection->client_ip = apr_pstrdup(rcr->r->connection->pool, rcr->old_ip); + rcr->r->connection->client_addr->sa.sin.sin_addr.s_addr = apr_inet_addr(rcr->r->connection->client_ip); return APR_SUCCESS; } @@ -161,7 +161,7 @@ if (!cfg->enable) return DECLINED; - if (is_in_array(r->connection->remote_ip, cfg->proxy_ips) == 1) { + if (is_in_array(r->connection->client_ip, cfg->proxy_ips) == 1) { /* check if cfg->headername is set and if it is use that instead of X-Forwarded-For by default */ if (cfg->headername && (fwdvalue = apr_table_get(r->headers_in, cfg->headername))) { @@ -180,11 +180,11 @@ if (*fwdvalue != '\0') ++fwdvalue; } - rcr->old_ip = apr_pstrdup(r->connection->pool, r->connection->remote_ip); + rcr->old_ip = apr_pstrdup(r->connection->pool, r->connection->client_ip); rcr->r = r; apr_pool_cleanup_register(r->pool, (void *)rcr, rpaf_cleanup, apr_pool_cleanup_null); - r->connection->remote_ip = apr_pstrdup(r->connection->pool, ((char **)arr->elts)[((arr->nelts)-1)]); - r->connection->remote_addr->sa.sin.sin_addr.s_addr = apr_inet_addr(r->connection->remote_ip); + r->connection->client_ip = apr_pstrdup(r->connection->pool, ((char **)arr->elts)[((arr->nelts)-1)]); + r->connection->client_addr->sa.sin.sin_addr.s_addr = apr_inet_addr(r->connection->client_ip); if (cfg->sethostname) { const char *hostvalue; if (hostvalue = apr_table_get(r->headers_in, "X-Forwarded-Host")) {
save the above codes in text file and apply the patch using the following command.
patch -p1 < patch_mod_rpaf